Bnc 1201 - 6 1/2 Digit Digital Multimeter Instrukcja Użytkownika Strona 88

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 177
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 87
89
Observe the displayed reading.
Figure 4-22 shows the locations of these buttons with red rectangle
frames.
Note: Press SHIFT+NULL again to disable this feature. The “MATH”
anunnciator on the display indicates the state of a mathematical feature.
Figure 4-22
Remote Interface Operation
Use the following commands from your PC terminal to make the dB
measurement:
CALCulate:FUNCtion DB
CALCulate:STATe {OFF|ON}
CALCulate:STATe?
CALCulate:DB:REFerence {<value>|MINimum|MAXimum}
B. dBm
Definition
With dBm selected, a voltage measurement is displayed as the level of
power, relative to 1 milliwatt, dissipated through a reference resistance.
The reference resistance is adjustable in 1201. The calculation of dBm is
defined as below:
mW
Z
V
dB
ref
in
m
1/log10
2
Note:
in
V is the input signal voltage.
ref
Z is the reference resistance.
Note: Change of reference resistance will not affect the stored relative
or
Przeglądanie stron 87
1 2 ... 83 84 85 86 87 88 89 90 91 92 93 ... 176 177

Komentarze do niniejszej Instrukcji

Brak uwag