5 SCPI Command Description
:ABORt Subsystem
The :ABORt command is a single command subsystem. There are no subcommands or associated
data parameters, as shown below. The :ABORt command, along with the :TRIGger and :INITiate
commands, comprise the Trigger group of commands.
(default)
:ABORt
This command causes measurement or sweep in progress to abort. Even if INIT:CONT[:ALL] is set to
ON, the sweep will not immediately re-initiate.
:CALCulate Subsystem
The CALCulate subsystem performs post acquisition data processing. Functions in the SENSe
subsystem are related to data acquisition, while the CALCulate subsystem operates on the data
acquired by a SENSe function.
The subsystem works for BB (baseband noise), and PN (phase noise), respectively.
(default)
N}
:CALCulate:PN:TRACe:FREQuency?
:CALCulate:PN:TRACe:SPECtrum?
:CALCulate:BB:TRACe:NOIse?
:CALCulate:PN:TRACe:SPURious:FREQuency?
:CALCulate:PN:TRACe:SPURious:POWer?
:CALCulate:PN:TRACe:FUNCtion:AVARiance?